Generator 40 kW
- Fuel: Diesel
- Grade: Commercial, Emergency, Industrial, Professional
- Style: Emergency Standby Generator, Portable Generator, Skid Mounted Generator, Towable Generator
- Starting: Electric (Auto Start Incl)
- Watts (Rated): 36,000
- Watts (Surge): 40,000
- Engine: Isuzu
- Compliance: All 50 States
- Prime rating 36kW (45kVA) / standby rating 40kW (50kVA)
- 49 hour run time @ 50% load and 1.6 gallon/hour fuel consumption; large fuel tank allows for over 27 hour run time @ 100% load
- Simultaneous single and three-phase power allowing available 120V GFCI duplex receptacles to be powered anytime generator is running
- Isuzu 4-cycle, direct injection, turbocharged, air-cooled 65HP diesel engine
- Incredibly low operating noise level of 66 dB(A)
- Automatic start and stop control allowing generator to start from remote location when used in conjunction with transfer switch
- Brushless alternator reduces service and maintenance requirements, meets temperature rise standards for class H insulation systems
- Electronic governor isynchronous control maintains frequency to ± 0.25% from no load to full load
- 79.2 gallon internal fuel tank (skid-mount capacity) with direct mount easy reading fuel gauge
- Voltage selector switch allows easy to change voltages as applications require
- Convenient generator operator analog control panel provides readouts and functionality; includes AC ammeter, AC voltmeter, frequency meter, voltage regulator, ammeter phase selector switch, voltmeter phase selector switch, AC circuit breaker, engine gauges, and more
- Automatic safety shutdown system monitors water temperature, engine oil pressure, overspeed, and overcrank
- EPA emissions ceritified; tier 4 final emissions compliance
- Fluid spill containment system with bonded design uniquely built into generator, can capture up to 124% of engine fluids
- Manually activated Emergency Stop Switch shuts down the generator in the event of an emergency.
The Multiquip WhisperWatt Super-Silent DCA45SSIU4F portable diesel generator is at the top of its class when it comes to providing standby or portable power to your construction project, event, military exercise, or other professional operations. If you run single phase 120V tools or lights and 3-phase submersible pumps or other tools, then you will be happy to know that the DCA45SSIU4F is capable of supporting your operations with its industry first switchable and even simultaneous single phase and 3-phase power capabilities. Operations requiring 100% load for over 24 hours will also find what they are looking for in this unit so the focus can remain on the task at hand and not constantly re-fueling your generator. Multiquip engineers their top pedigree of portable super-silent diesel generators to maximize functionality, durability, and longevity of ownership so that whether your temporary portable power is required during a life threatening disaster relief and recovery situation, on the job site with a full crew ready to work, or simply during a weekend sporting event, you can count on the your Multiquip diesel generator to stand up when you need it most.
*Delivery of the Multiquip DCA45 will require a commercial dock or forklift unloading by client.
Additional information
Fuel Type |
---|
Features
Product
- Manufacturer: Multiquip
- SKU: DCA45SSIU4F
- Model Number: DCA45SSIU4F
- Generator Grade: Commercial, Emergency, Industrial, Professional
- Generator Style: Emergency Standby Generator, Portable Generator, Skid Mounted Generator, Towable Generator
- Special Features: 1800 RPM, 3-Phase, 50 Amp Plug, Brushless Alternator, Fuel Gauge, GFCI Protection – Partial, Hour Meter, Liquid Cooled, Voltmeter
Engine Details
- Engine/Motor Brand: Isuzu
- Engine Model: 4LE2X
- Fuel Type: Diesel
- Starting System: Electric (Auto Start Incl)
- Horsepower: 65.7 HP
- Engine/Motor Type: 4-Cylinder, Water-Cooled, Charged Air Cooled, 4-Cycle, Direct Injected, Turbo-Charged, EGR
- Displacement: 2180 cc
- Engine RPM: 1800 RPM
- Generator RPM: 1800 RPM
- Fuel Capacity: 79.20 Gallons
- Run Time @ 25% Ld (Hrs): 76.2
- Run Time @ 50% Ld (Hrs): 49.5
- Run Time @ 100% Ld (Hrs): 27.0
- Fuel Cons. @ 50% Ld: 1.60 Gallons/Hour
- Fuel Cons. @ 100% Ld: 2.93 Gallons/Hour
- Fuel Gauge: Included
- Enclosure: Sound-Attenuating
- Low Oil Shutdown/Alert: Yes
- Operational Volume (dB @23ft): 66.0
- Overload Protection: Yes
- Altitude Affected: Yes, Call For More Information
Accessories
- Portability/Wheel Kit: Add @ Checkout
- Battery For Electric Start: Included
Warranty
- Engine Warranty: 2 Years Or 2000 Hours
- Generator Warranty: 2 Years Or 2000 Hours
Other Information
- Weight (Lbs.): 2282
- Ship Weight (Lbs.): 2432
- Operating Weight (Lbs.): 2976
- Free Shipping: No
- Dimension No Wheel Kit: 84.0″L x 38.0″W x 61.0″H
- Agency Compliance: CARB (California), EPA Tier 4 Final, TAA (Trade Agreement Act) Compliant
- California Destination-Operators-Buyers Warning: Click Here For California Proposition 65 Warning
- Stk. Itm.: No
Generator Details
- Surge Start Watts: 40,000.0
- Continuous Rated Watts: 36,000.0
- Prime Rating Watts: 36,000
- Standby Rating Watts: 40,000
- Phase: Single-Phase, 3-Phase, Simultaneous 1 & 3 Phase (Limited)
- Phase & Voltage Selection: 3-Position Phase & Voltage Selector Switch
- Voltage: 120, 127, 139, 240/254, 277 1-Phase, 208, 220, 240, 416, 440, 460, 480 3-Phase Switchable
- Rated Amps @ Min Volt (Commonly 120v): 216.0
- Rated Amps @ Max Volt (Commonly 240v 1-Phase): 108.0
- Rated Amps @ 240 Volts (3-Phase): 108.0
- Rated Amps @ 480 Volts (3-Phase): 54.0
- GFCI Panel Protection: Partial
- Parallel Operation Control: No
- Frequency: 60 Hz
- Poles: 4
- Alternator: Brushless
- Voltage Regulation: Auto Voltage Regulation
- Frequency Regulation: +/- 0.25% With Electronic Governor
- Circuit Breakers: Yes
- Continuous Battery Charge: Add @ Checkout
- Control Panel Display: Voltmeter, Voltage Selector Switch, Ammeter, DC Ammeter, Frequency Meter, Hour Meter, Tachometer, Oil Pressure Gauge, Water Temperature Gauge, Preheat Indicator, LED, Panel Light, Ammeter Phase Selector Switch, Voltmeter Phase Selector Switch, Voltage Regulator Control, Automatic Safety Shutdown System Monitors: Water Temp, Engine Oil Pressure, Overspeed, and Overcrank. Warning Lights Indicate Abnormal Conditions.